MPF
Menegotto-Pinto-Filippou Steel Model
Syntax
History Variable Layout
location | value |
---|---|
initialize_history(0) |
reverse_stress |
initialize_history(1) |
reverse_strain |
initialize_history(2) |
intermediate_stress |
initialize_history(3) |
intermediate_strain |
initialize_history(4) |
previous_intermediate_strain |
initialize_history(5) |
max_strain |
initialize_history(6) |
load_sign |
Remarks
- The isotropic hardening switch can be turned on to use Filippou's modification.
- If constant radius switch is on,
is unchanged.